Item

ODYSSEY® model (Ah @ 10 hr. rate)

PC 535 (13Ah)

PC 545 (12Ah)

PC 680 (16Ah)

PC 625 (16Ah)

PC 925 (27Ah)

PC 1200 (40Ah)

PC 1700 (65Ah)

5 sec. hot cranking amps (HCA)
535A
545A
680A
625A
925A
1200A
1700A

CCA

200A

170A

210A

265A

360A

530A

840A

CA @32°F

265A

225A

270A

350A

455A

675A

1055A

HCA @80°F

300A

300A

370A

440A

625A

860A

1325A

Reserve capacity 4

21 min.

18 min.

24 min.

27 min.

50 min.

78 min.

142 min.

Terminals

Female threaded for M6 SS bolt

SAE combination post with 3/8" top thread

Max. installation torque, in-lb.

40

50

50

60

60

60

60

Length, in. (mm.) 1

6.70 (170.2)

7.00 (177.8)

7.27 (184.7)

6.70 (170.2)

6.64 (168.6)

7.87 (199.9)

13.02 (330.7)

Width, in. (mm.)

3.90 (99.1)

3.37 (85.6)

3.11 (79.0)

3.90 (99.1)

7.05 (179.0)

6.66 (169.1)

6.62 (168.2)

Height, in. (mm.) 2

6.125 (155.6)

5.17 (131.3)

6.67 (169.4)

6.89 (175.0)

5.04 (128.0)

6.80 (172.7)

6.93 (176.0)

Weight, lb. (kg.) 3

12.0 (5.4)

12.6 (5.7)

15.4 (7.0)

13.2 (6.0)

26.0 (11.8)

38.2 (17.4)

60.9 (27.6)

Cycle life @77°F

400 at 100% DOD and 14.7V charge for 16 to 24 hours
500 at 80% DOD and 14.7V charge for 16 to 24 hours

Temperature range

- 40°C (- 40°F) to + 45°C (113°F) for PC 535 & PC 625
- 40°C (- 40°F) to + 80°C (176°F) with metal jacket on all other sizes

Resistance at 1 kHz @77°F

8m Ohm

10m Ohm

7m Ohm

7m Ohm

5m Ohm

4.5m Ohm

3.5m Ohm

Short ckt. current

> 1,000A

> 1,200A

> 1,800A

> 1,800A

> 2,400A

> 2,600A

> 3,500A

1 Length dimensions measured on terminal side and include metal jacket, except on PC 535 and PC 625.
2 Add 0.75" for automotive terminals (available ONLY on PC 680, PC 925, PC 1200 and PC 1700)
3 PC 535 and PC 625 do not have metal jackets; all other weights include metal jackets
4 Reserve capacity measured on a 25amp draw


ODYSSEY® Battery Pulse Discharge Capabilities

The graph titled ODYSSEY® pulse discharge per battery shown below demonstrates the extraordinary short duration (pulse) discharge capabilities of the ODYSSEY® family of batteries. Note that the discharge figures are shown for an ambient temperature of 25°C and to an end of discharge voltage (EODV) of 7.20V per 12V battery.

ODYSSEY® pulse discharge per battery

Two points should be kept in mind when using this battery for such extreme high-rate discharges. First, sufficient time must be given between two successive discharges to allow the terminals to cool down. Second, the graph reflects the capabilities of fully charged ODYSSEY® batteries. Unless the batteries are fully charged, one must not expect them to meet these numbers. Finally, all of these numbers are for an ambient temperature of 25°C; if the temperature is significantly different from 25°C, the graph shown above must be appropriately modified.

Table I below provides the five, ten and twenty second pulse discharge numbers for the ODYSSEY® line of Drycell™ batteries.

Table I

Battery

Pulse discharge in amps to 7.2V

 

5 sec.

10 sec.

20 sec.

PC545

545

495

420

PC680

680

595

525

PC625

625

545

480

PC925

925

870

765

PC1200

1200

1090

900

PC1700

1700

1540

1355


Storage and Recharge Criteria

For any rechargeable battery, storage and recharge are important criteria, and this section develops some useful guidelines that should be followed. 

(A) How do I know the state of charge of the battery? Provided the battery has not been charged or discharged for at least five (5) hours, one can use the following graph to determine the state of charge (SOC) of the ODYSSEY® battery by simply using a good quality digital voltmeter to measure its open circuit voltage (OCV).

The graph below indicates that a healthy, fully charged ODYSSEY® battery will have an open circuit voltage of 12.84V or higher at 25ºC

The open circuit voltage (OCV) numbers on this graph are applicable only if the battery has not seen any activity (charge or discharge) for at least a few hours before voltage measurements are taken.

ODYSSEY® OCV vs. state of charge
® OCV vs. state of charge

(B) How long can the battery be stored?
The next graph shows the remarkable storage properties of the ODYSSEY® battery. At a storage temperature of 25°C, one can store these batteries for up to two (2) years. As the graph illustrates, the lower the storage temperature, the longer the storage time.

The graph also illustrates the large impact of temperature on storage — for every approximately 10°C (18°F) increase in temperature the storage time is cut in half. Thus, although the ODYSSEY® battery may be kept on the shelf for two years at 25°C (77°F), if the temperature rises to about 35°C the battery may be stored for only one year before it needs a recharge.

The numbers on this graph are applicable only if the battery is fully charged before being placed on storage..

ODYSSEY® storage time vs. temperature

(C) Can the battery recover from abusive storage conditions?
The short answer is yes, the ODYSSEY® battery can recover from extremely deep discharges as the following tests demonstrate.

(1) German DIN standard test for overdischarge recovery
In this test, a charged ODYSSEY® PC925 battery was fully discharged over 20 hours (0.05C10 rate) to 10.20V. After the discharge was complete, a 5W resistor was placed across the battery terminals and it was set aside for 28 days.

At the end of 28 days’ of storage, the battery was charged at 13.5V for only 48 hours. Another 0.05C10 discharge yielded 97% of rated capacity, indicating that a 48-hour charge after such as deep discharge was not sufficient; however, the test is designed to show whether the battery can be recovered from extremely deep discharges using only a standby float charger. A standard automotive charger at 14.4V would have allowed the battery to recover greater than 97% of its capacity.

The results of this test prove rather conclusively that ODYSSEY® batteries can indeed recover from very abusive storage conditions. This conclusion is further reinforced by the following test which is even harsher than the DIN standard test due to the fact that the battery was stored in a discharged state at a high temperature of 50°C or 112°F.

(2) High temperature (50°/112°F) discharged storage test
In this test two ODYSSEY® battery samples were discharged at the 1-hour rate to 9V per module, then set aside for storage at 50°C (112°F) in a discharged condition for four weeks.

At the end of four weeks the two batteries were recharged using a constant voltage (CV) charger at 14.7V per battery. As the graph below shows, both samples were able to recover nicely from this extreme case of abusive storage.

Recovery from high temperature (50°C) discharged storage
(Constant voltage recharge at 14.7V per module)

Sealed Rechargeable DrycellTM - Deep Cycle Batteries